Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Financial Programs
- Downpayment>49%
- Period36 months
- Rate0%
%
Period
Leasing agreement amount
Payment type
Annuity
Monthly payment
/ month
Generator Set Specifications
- Standby Rating
- 2,500/2,250/2,000 ekW
- Prime Power Rating
- 2,250/2,045/1,825 ekW
- Emissions/Fuel Strategy
- U.S. EPA Cert., Tier 2
- Voltage
- 380 to 13,800 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby, Mission Critical, Prime, Continuous
- Maximum Rating
- 2,500 ekW
- Minimum Rating
- 1,650 ekW
Engine Specifications
- Engine Model
- 3,516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel
- Bore
- 6.69 in
- Stroke
- 7.48 in
- Stroke - HD
- 8.46 in
- Displacement
- 4,764.73 in
- Compression Ratio
- 14.7:1
- Aspiration
- TA
- Fuel System
- Electronic unit injection
- Governor Type
- Adem™3
Generator Set Dimensions
- Length - Minimum
- 284.6 in
- Length - Maximum
- 295.1 in
- Width - Minimum
- 93.7 in
- Width - Maximum
- 101.2 in
- Height - Minimum
- 116.5 in
- Height - Maximum
- 118.5 in
- Dry Weight - Genset (minimum)
- 35,880 lb
- Dry Weight - Genset (maximum)
- 38,780 lb
Standard Equipment:
- Air Inlet System
- Air cleaner; single element canister type
- Cooling
- Package mounted radiator
- Exhaust
- Exhaust flange outlet
- Control Panels
- Communications:
- Reverse reactive power (kVAr) (32RV)
- Customer data link (Modbus RTU)
- Generator mounted - rear facing
- 1 Programmable digital outputs
- Auto/start/stop control -
- Serial annunciator module data link
- Engine cool-down timer
- 24 Volt DC operation
- Controls:
- Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
- Alarm acknowledge
- Cat connect
- Engine cycle crank
- Text alarm/event descriptions
- Overcurrent (50 / 51)
- Accessory module data link
- Cat ECS 100
- 1 Programmable relay outputs (Form C)
- Emergency stop pushbutton
- Speed adjust
- 4 Programmable relay outputs (Form A)
- Number of I/O varies on options selected
- 6 Customer programmable digital inputs
- Environmental sealed front face
- Load histogram feature
- Lamp test
- PLC functionality
- Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
- Digital indication for:
- Operating hours
- RPM
- DC volts
- Frequency (Hz)
- Coolant temperature
- Volts (L-L & L-N)
- Oil pressure (psi, kPa or bar)
- Amps (per phase & average)
- kVAr (per phase, average & percent)
- kVA (per phase, average & percent)
- kW (per phase, average & percent)
- Power factor (per phase & average)
- kW-hr (total)
- kVAr-hr (total)
- High coolant temperature
- Overspeed
- Failure to start (overcrank)
- Warning/shutdown with common LED indication of shutdowns for:
- Emergency stop
- Low oil pressure
- Low coolant level
- Low coolant temperature
- Programmable protective relaying functions:
- Over/under frequency (81 o/u)
- Generator phase sequence
- Over/under voltage (27 / 59)
- Reverse power (kW) (32)
- Fuel
- Primary fuel filter with integral water separator
- Generator
- Matched to the performance and output characteristics of Cat engines
- IP23 Protection
- Power Termination
- Busbar
- Control Panel
- Cat ECS Genset controller
- Cooling System
- Certified standard PGS provided
- Exhaust System
- Flanged faced outlet(s)
- Dry exhaust manifold
- Fuel System
- Flexible fuel lines - shipped loose
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
- Fuel priming pump
- General
- Caterpillar yellow with high gloss black rails and radiator
- Right hand servicing
- Flywheel and flywheel housing - SAE No. 00
- Paint - Caterpillar yellow except rails and radiators gloss black
- SAE standard rotation
- Generator And Attachments
- Busbar connections, top center mounted, top cable entry
- Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Low voltage:
- NEMA standard hole pattern
- Medium voltage:
- Anti-condensation space heater
- 6 Lead
- Random wound
- Form wound
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Permanent magnet excitation (PMG)
- Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
- Internal excitation (IE)
- 3 Phase brushless, Salient pole
- High voltage:
- Winding temperature detectors
- Busbar connections, right side extension box, bottom cable entry
- Governing System
- ADEM A3
- Literature
- Parts book
- Lubrication System
- Lubricating oil
- Fumes disposal
- Integral lube oil cool
- Oil drain lines and valve
- Oil filter, filler and dipstick
- Gear type lube oil pump
- Mounting System
- Anti-vibration mounts (shipped loose)
- Rubber anti-vibration mounts - shipped loose
- Rails - engine/generator/radiator mounting
- Starting System
- Battery disconnect switch
- 45 Amp Charging alternator
- 24 Volt electric starting motor
- Battery and battery rack w/cables
Optional Equipment:
- Control System
- EMCP 4.4
- Exhaust
- Exhaust mufflers
- Air Inlet System
- Single element filter
- Dual element air cleaner
- Generator
- Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
- Oversize and premium generators
- Anti-condensation heater
- Cooling System
- Coolant
- Standard ambient ATAAC radiators
- Optional installed radiators
- Optional installed ATAAC radiators
- Standard ambient radiators
- Water level switch gauges
- Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
- Crankcase System
- Explosion relief valves
- Ventilation system
- No explosion relief valves
- Control Panels
- Load share module
- Digital I/O module
- Generator temperature monitoring & protection
- Remote monitoring software
- Mounting
- Rubber anti-vibration mounts
- IBC isolators
- Exhaust System
- Y Adapters
- Flexible fittings
- Exhaust offset
- Tier 4 clean emissions module
- Elbows
- Flange and exhaust expanders
- Tier 4 clean emission MOD Kits
- Tier 4 dosing cabinet
- Flanges
- Mufflers
- Clean emission parts
- Starting/charging
- Oversize batteries
- Battery chargers
- Charging alternator
- Air starting motor with control and silencer
- Heavy duty starting system
- Fuel System
- Primary fuel filter
- General
- The following options are based on regional and product configuration:
- UL 2200 package
- CSA Certification
- EEC Declaration of Conformity
- Special paint (Colors other than Caterpillar yellow or high performance paints)
- Integral & sub-base fuel tanks
- US aid emblem
- Enclosures: Sound attenuated, weather protective
- Automatic transfer switches (ATS)
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- EU Certificate of Conformance (CE)
- Integral & sub-base UL listed dual wall fuel tanks
- Generators And Attachments
- High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
- High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
- Thermostat for space heater
- Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
- Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Generator conversion
- Space heater kit
- Alternator air cleaner
- Instrumentation
- Pyrometer and thermocouples
- Lubrication System
- Oil level regulator
- Lube oil in standard sump
- Prelube pumps
- Mounting System
- Puck style low efficiency isolators
- Spring type vibration isolators
- IBC vibration isolators
- Power Connections
- Ground cables between generator and terminal box
- Neutral ground connections
- Left side power connections
- Center post busbars
- Right side power connections
- 2700 Frame, four lead, four terminal
- Rear power connections
- Low voltage Circuit breakers
- Special Tests / Reports
- IBC Certification
- Fuel consumption test
- Generator test report
- PGS Test report @ 1.0 power factor
- Torsional vibration analysis reports
- OSHPD Certification
- Generator set fuel consumption test
- PGS Test report @ 0.8 power factor
- Standard engine test charge
- Canadian Standards Association certification
- Starting And Charging
- Air pressure regulator
- Starter cover
- Air starting motors
- 10, 20, 35 and 50 Amp Battery chargers
- Electric starting motors
- Jacket water heaters
- 24 Volt battery set - Dry
- Engine barring device
- Extended Service Coverage
- Platinum, Gold and Silver coverage
Specifications
Generator Set Specifications
- Standby Rating
- 2,500/2,250/2,000 ekW
- Prime Power Rating
- 2,250/2,045/1,825 ekW
- Emissions/Fuel Strategy
- U.S. EPA Cert., Tier 2
- Voltage
- 380 to 13,800 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby, Mission Critical, Prime, Continuous
- Maximum Rating
- 2,500 ekW
- Minimum Rating
- 1,650 ekW
Engine Specifications
- Engine Model
- 3,516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel
- Bore
- 6.69 in
- Stroke
- 7.48 in
- Stroke - HD
- 8.46 in
- Displacement
- 4,764.73 in
- Compression Ratio
- 14.7:1
- Aspiration
- TA
- Fuel System
- Electronic unit injection
- Governor Type
- Adem™3
Generator Set Dimensions
- Length - Minimum
- 284.6 in
- Length - Maximum
- 295.1 in
- Width - Minimum
- 93.7 in
- Width - Maximum
- 101.2 in
- Height - Minimum
- 116.5 in
- Height - Maximum
- 118.5 in
- Dry Weight - Genset (minimum)
- 35,880 lb
- Dry Weight - Genset (maximum)
- 38,780 lb
Standard/Optional Features
Standard Equipment:
- Air Inlet System
- Air cleaner; single element canister type
- Cooling
- Package mounted radiator
- Exhaust
- Exhaust flange outlet
- Control Panels
- Communications:
- Reverse reactive power (kVAr) (32RV)
- Customer data link (Modbus RTU)
- Generator mounted - rear facing
- 1 Programmable digital outputs
- Auto/start/stop control -
- Serial annunciator module data link
- Engine cool-down timer
- 24 Volt DC operation
- Controls:
- Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
- Alarm acknowledge
- Cat connect
- Engine cycle crank
- Text alarm/event descriptions
- Overcurrent (50 / 51)
- Accessory module data link
- Cat ECS 100
- 1 Programmable relay outputs (Form C)
- Emergency stop pushbutton
- Speed adjust
- 4 Programmable relay outputs (Form A)
- Number of I/O varies on options selected
- 6 Customer programmable digital inputs
- Environmental sealed front face
- Load histogram feature
- Lamp test
- PLC functionality
- Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
- Digital indication for:
- Operating hours
- RPM
- DC volts
- Frequency (Hz)
- Coolant temperature
- Volts (L-L & L-N)
- Oil pressure (psi, kPa or bar)
- Amps (per phase & average)
- kVAr (per phase, average & percent)
- kVA (per phase, average & percent)
- kW (per phase, average & percent)
- Power factor (per phase & average)
- kW-hr (total)
- kVAr-hr (total)
- High coolant temperature
- Overspeed
- Failure to start (overcrank)
- Warning/shutdown with common LED indication of shutdowns for:
- Emergency stop
- Low oil pressure
- Low coolant level
- Low coolant temperature
- Programmable protective relaying functions:
- Over/under frequency (81 o/u)
- Generator phase sequence
- Over/under voltage (27 / 59)
- Reverse power (kW) (32)
- Fuel
- Primary fuel filter with integral water separator
- Generator
- Matched to the performance and output characteristics of Cat engines
- IP23 Protection
- Power Termination
- Busbar
- Control Panel
- Cat ECS Genset controller
- Cooling System
- Certified standard PGS provided
- Exhaust System
- Flanged faced outlet(s)
- Dry exhaust manifold
- Fuel System
- Flexible fuel lines - shipped loose
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
- Fuel priming pump
- General
- Caterpillar yellow with high gloss black rails and radiator
- Right hand servicing
- Flywheel and flywheel housing - SAE No. 00
- Paint - Caterpillar yellow except rails and radiators gloss black
- SAE standard rotation
- Generator And Attachments
- Busbar connections, top center mounted, top cable entry
- Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Low voltage:
- NEMA standard hole pattern
- Medium voltage:
- Anti-condensation space heater
- 6 Lead
- Random wound
- Form wound
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Permanent magnet excitation (PMG)
- Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
- Internal excitation (IE)
- 3 Phase brushless, Salient pole
- High voltage:
- Winding temperature detectors
- Busbar connections, right side extension box, bottom cable entry
- Governing System
- ADEM A3
- Literature
- Parts book
- Lubrication System
- Lubricating oil
- Fumes disposal
- Integral lube oil cool
- Oil drain lines and valve
- Oil filter, filler and dipstick
- Gear type lube oil pump
- Mounting System
- Anti-vibration mounts (shipped loose)
- Rubber anti-vibration mounts - shipped loose
- Rails - engine/generator/radiator mounting
- Starting System
- Battery disconnect switch
- 45 Amp Charging alternator
- 24 Volt electric starting motor
- Battery and battery rack w/cables
Optional Equipment:
- Control System
- EMCP 4.4
- Exhaust
- Exhaust mufflers
- Air Inlet System
- Single element filter
- Dual element air cleaner
- Generator
- Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
- Oversize and premium generators
- Anti-condensation heater
- Cooling System
- Coolant
- Standard ambient ATAAC radiators
- Optional installed radiators
- Optional installed ATAAC radiators
- Standard ambient radiators
- Water level switch gauges
- Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
- Crankcase System
- Explosion relief valves
- Ventilation system
- No explosion relief valves
- Control Panels
- Load share module
- Digital I/O module
- Generator temperature monitoring & protection
- Remote monitoring software
- Mounting
- Rubber anti-vibration mounts
- IBC isolators
- Exhaust System
- Y Adapters
- Flexible fittings
- Exhaust offset
- Tier 4 clean emissions module
- Elbows
- Flange and exhaust expanders
- Tier 4 clean emission MOD Kits
- Tier 4 dosing cabinet
- Flanges
- Mufflers
- Clean emission parts
- Starting/charging
- Oversize batteries
- Battery chargers
- Charging alternator
- Air starting motor with control and silencer
- Heavy duty starting system
- Fuel System
- Primary fuel filter
- General
- The following options are based on regional and product configuration:
- UL 2200 package
- CSA Certification
- EEC Declaration of Conformity
- Special paint (Colors other than Caterpillar yellow or high performance paints)
- Integral & sub-base fuel tanks
- US aid emblem
- Enclosures: Sound attenuated, weather protective
- Automatic transfer switches (ATS)
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- EU Certificate of Conformance (CE)
- Integral & sub-base UL listed dual wall fuel tanks
- Generators And Attachments
- High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
- High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
- Thermostat for space heater
- Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
- Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Generator conversion
- Space heater kit
- Alternator air cleaner
- Instrumentation
- Pyrometer and thermocouples
- Lubrication System
- Oil level regulator
- Lube oil in standard sump
- Prelube pumps
- Mounting System
- Puck style low efficiency isolators
- Spring type vibration isolators
- IBC vibration isolators
- Power Connections
- Ground cables between generator and terminal box
- Neutral ground connections
- Left side power connections
- Center post busbars
- Right side power connections
- 2700 Frame, four lead, four terminal
- Rear power connections
- Low voltage Circuit breakers
- Special Tests / Reports
- IBC Certification
- Fuel consumption test
- Generator test report
- PGS Test report @ 1.0 power factor
- Torsional vibration analysis reports
- OSHPD Certification
- Generator set fuel consumption test
- PGS Test report @ 0.8 power factor
- Standard engine test charge
- Canadian Standards Association certification
- Starting And Charging
- Air pressure regulator
- Starter cover
- Air starting motors
- 10, 20, 35 and 50 Amp Battery chargers
- Electric starting motors
- Jacket water heaters
- 24 Volt battery set - Dry
- Engine barring device
- Extended Service Coverage
- Platinum, Gold and Silver coverage