ATC Service Entrance Rated MCCB & Power Breaker Based ATS 11253

ATC Service Entrance Rated MCCB & Power Breaker Based ATS
11253 ATC Service Entrance Rated MCCB & Power Breaker Based ATS

Cat® Service Entrance Rated (SER) automatic transfer switches (ATS) are designed to provide standby power emergency power to entire installation loads to protect against utility power interruption; yet allow the ATS to be as close as possible to the point of service entrance. By safely and in code compliance, integrating the necessary overcurrent protection and service disconnecting means into the automatic transfer switch, a single installation can be made at the service entrance. This design eliminates the need for a separate upstream fault protection and respective interconnections, which in turn reduces installation space, time, and cost. Breaker-based Service Entrance Rated transfer switches are available from 30A to 5000A.

CAT
Power Systems
Price: Request a Quote

Cat® Service Entrance Rated (SER) automatic transfer switches (ATS) are designed to provide standby power emergency power to entire installation loads to protect against utility power interruption; yet allow the ATS to be as close as possible to the point of service entrance. By safely and in code compliance, integrating the necessary overcurrent protection and service disconnecting means into the automatic transfer switch, a single installation can be made at the service entrance. This design eliminates the need for a separate upstream fault protection and respective interconnections, which in turn reduces installation space, time, and cost. Breaker-based Service Entrance Rated transfer switches are available from 30A to 5000A.

Rating Range
30-5,000A
Transfer Type
Open / Closed / Delayed
Switch Type
Molded Case and Power Breaker
MCCB
30-1,000A 2, 3, or 4 Pole

Financial Programs

  • Downpayment
    >49%
  • Period
    36 months
  • Rate
    0%
%
Period
Leasing agreement amount
Payment type
Annuity
Monthly payment
/ month

Technical Summary

Rating Range
30-5,000A
Transfer Type
Open / Closed / Delayed
Switch Type
Molded Case and Power Breaker

Ratings

MCCB
30-1,000A 2, 3, or 4 Pole
Fixed Mount Power Breaker
200-3,200A 2, 3, 4-Pole
Drawout Power Breaker
200-5,000A 2, 3, or 4-Pole
System Voltage Application
120-600 Vac 50/60 Hz
Withstand
(Power Breaker) Up to 100 kAIC at 600V 3 cycles
Applicable Testing

UL 1,008 listed up to 3,200A

4,000A, and 5,000A UL 891 listed

Standard Equipment:

  • Controls And Wiring
    • All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.
  • Enclosure
    • Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.

Optional Equipment:

  • Available Options
    • 4-position test switch
    • Remote communications
    • Surge suppression
    • Selectable automatic or non-automatic operation
    • Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC and OSHPD)
    • Communications for the ATC-300+ controller via RS-232 or Modbus through an integrated RS-485 port
    • Field selectable, multi ratio, control voltage transformer 50/60 Hz
    • Load sequencing contacts
    • Multi-meter options available
    • Open, closed or delayed transition
    • Space heaters
    • Integral overcurrent protection
  • Optional Delayed Transition Includes:
    • Pre-transfer signal with 1 N.O. and 1 N.C. contacts
    • Time delay neutral

Specifications

Technical Summary

Rating Range
30-5,000A
Transfer Type
Open / Closed / Delayed
Switch Type
Molded Case and Power Breaker

Ratings

MCCB
30-1,000A 2, 3, or 4 Pole
Fixed Mount Power Breaker
200-3,200A 2, 3, 4-Pole
Drawout Power Breaker
200-5,000A 2, 3, or 4-Pole
System Voltage Application
120-600 Vac 50/60 Hz
Withstand
(Power Breaker) Up to 100 kAIC at 600V 3 cycles
Applicable Testing

UL 1,008 listed up to 3,200A

4,000A, and 5,000A UL 891 listed

Standard/Optional Features

Standard Equipment:

  • Controls And Wiring
    • All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.
  • Enclosure
    • Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.

Optional Equipment:

  • Available Options
    • 4-position test switch
    • Remote communications
    • Surge suppression
    • Selectable automatic or non-automatic operation
    • Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC and OSHPD)
    • Communications for the ATC-300+ controller via RS-232 or Modbus through an integrated RS-485 port
    • Field selectable, multi ratio, control voltage transformer 50/60 Hz
    • Load sequencing contacts
    • Multi-meter options available
    • Open, closed or delayed transition
    • Space heaters
    • Integral overcurrent protection
  • Optional Delayed Transition Includes:
    • Pre-transfer signal with 1 N.O. and 1 N.C. contacts
    • Time delay neutral