Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Financial Programs
- Downpayment>49%
- Period36 months
- Rate0%
%
Period
Leasing agreement amount
Payment type
Annuity
Monthly payment
/ month
Generator Set Specifications
- Maximum Rating
- 300 ekW
- Minimum Rating
- 300 ekW
- Emissions/Fuel Strategy
- EPA Stationary Emergency
- Voltage
- 208 to 600 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- Cat® C9 In-line 6, 4-cycle diesel
- Bore
- 4.4 in
- Stroke
- 5.9 in
- Displacement
- 538 in³
- Compression Ratio
- 16.3:1
- Aspiration
- Turbocharged Air-to-Air Aftercooled
- Fuel System
- HEUI
- Governor Type
- Adem™A4
Generator Set Dimensions
- Length - Maximum
- 155.5 in
- Width - Minimum
- 56.3 in
- Width - Maximum
- 56.7 in
- Height - Minimum
- 67.2 in
- Height - Maximum
- 86.7 in
- Dry Weight - Genset (minimum)
- 5,518.2 lb
- Dry Weight - Genset (maximum)
- 6,929.1 lb
Standard Equipment:
- Air Inlet System
- Aftercooler core
- Turbocharger
- Air cleaner - Non canister, disposable
- Control Panel
- GCCP 1.2
- Cooling System
- Jacket water pump, gear driven, centrifugal
- Thermostats and housing
- Coolant drain valve
- Radiator sight gauge
- Blower fan and fan drive with guards
- Radiator, package mounted
- Exhaust System
- Exhaust manifold - dry
- Fuel System
- Integral tank base, 24 hours, UL142
- Fuel priming pump
- Engine fuel transfer pump
- Primary fuel filter w/integral water separator and secondary filter, spin on
- Generator Set
- Complete system designed & built at ISO 9001:2000 certified facilities
- All protective devices and control functions simulated and checked
- Factory tested to design specifications at full load conditions
- Generators And Generator Attachments
- IP23 Protection
- 12 Leads
- Insulation system, Class H
- Standard winding protection for non-harsh environments with relative humidity ? 95%
- Voltage regulator (single phase sensing)
- Easy access to AVR and terminals
- Terminal box, IP22 RHS facing, bottom cable entry
- Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
- Governing System
- Cat electronic governor (ADEM A4)
- Lube System
- Shallow oil pan
- Oil cooler
- Fumes disposal to front of radiator
- Oil drain with valve
- Oil filler and dipstick
- Oil filter, spin on
- Lubricating oil, CK-4 (10W-30)
- Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant and lube oil drain lines
- Protection
- Safety shutoff - High water temperature
- Safety shutoff - Low oil pressure
- Safety shutoff - Overspeed
- Starting/charging System
- 24-volt electric starting motor
- 24V, 45 Amp Charging alternator
- General
- Lifting eyes
- Vibration damper
- Parts book
Optional Equipment:
- Air Inlet System
- Air cleaner (Non canister disposable)
- Bases, Mounting & Fuel Tanks
- Integral tank base, 24 hours, UL142
- Audio & visual fuel alarm (@90% fuel level)
- Wide Base - Skid
- Fuel tank pill pipe & lockable cap
- Circuit Breaker
- 400A LSI
- 600A LSI
- 1200A LSI
- 800A LS/I
- Auxiliary contacts
- 600A LS/I
- 1200A LS/I
- 400A LS/I
- 800A LSI
- Control System
- Audible alarm Gp
- 16 -light NFPA 99/110 Annunciator
- Twist release, Red button emergency stop
- Ground fault relay
- 100A Load center
- Product link remote monitoring hardware
- 20A GFCI (Ground Fault Circuit Interrupter)
- Volt free contacts
- Enclosures
- Sound attenuated Level 2 enclosure (White)
- AC & DC Source lights
- E-Stop
- Exhaust System
- 6" Muffler - 25 dBA attenuation
- Manifold and turbocharger guards
- Flexible exhaust connection
- Generator
- Space heater
- Permanent magnet excitation (PMG) generator
- Starting System
- Battery charger (UL Certified)
- Jacket water heater
- Standard battery set: 1000 CCA, 90 amp/hr.
- General
- CSA Certification
- Extended Service Coverage
- UL2200 Certification
- Generator test report
Specifications
Generator Set Specifications
- Maximum Rating
- 300 ekW
- Minimum Rating
- 300 ekW
- Emissions/Fuel Strategy
- EPA Stationary Emergency
- Voltage
- 208 to 600 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- Cat® C9 In-line 6, 4-cycle diesel
- Bore
- 4.4 in
- Stroke
- 5.9 in
- Displacement
- 538 in³
- Compression Ratio
- 16.3:1
- Aspiration
- Turbocharged Air-to-Air Aftercooled
- Fuel System
- HEUI
- Governor Type
- Adem™A4
Generator Set Dimensions
- Length - Maximum
- 155.5 in
- Width - Minimum
- 56.3 in
- Width - Maximum
- 56.7 in
- Height - Minimum
- 67.2 in
- Height - Maximum
- 86.7 in
- Dry Weight - Genset (minimum)
- 5,518.2 lb
- Dry Weight - Genset (maximum)
- 6,929.1 lb
Standard/Optional Features
Standard Equipment:
- Air Inlet System
- Aftercooler core
- Turbocharger
- Air cleaner - Non canister, disposable
- Control Panel
- GCCP 1.2
- Cooling System
- Jacket water pump, gear driven, centrifugal
- Thermostats and housing
- Coolant drain valve
- Radiator sight gauge
- Blower fan and fan drive with guards
- Radiator, package mounted
- Exhaust System
- Exhaust manifold - dry
- Fuel System
- Integral tank base, 24 hours, UL142
- Fuel priming pump
- Engine fuel transfer pump
- Primary fuel filter w/integral water separator and secondary filter, spin on
- Generator Set
- Complete system designed & built at ISO 9001:2000 certified facilities
- All protective devices and control functions simulated and checked
- Factory tested to design specifications at full load conditions
- Generators And Generator Attachments
- IP23 Protection
- 12 Leads
- Insulation system, Class H
- Standard winding protection for non-harsh environments with relative humidity ? 95%
- Voltage regulator (single phase sensing)
- Easy access to AVR and terminals
- Terminal box, IP22 RHS facing, bottom cable entry
- Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
- Governing System
- Cat electronic governor (ADEM A4)
- Lube System
- Shallow oil pan
- Oil cooler
- Fumes disposal to front of radiator
- Oil drain with valve
- Oil filler and dipstick
- Oil filter, spin on
- Lubricating oil, CK-4 (10W-30)
- Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant and lube oil drain lines
- Protection
- Safety shutoff - High water temperature
- Safety shutoff - Low oil pressure
- Safety shutoff - Overspeed
- Starting/charging System
- 24-volt electric starting motor
- 24V, 45 Amp Charging alternator
- General
- Lifting eyes
- Vibration damper
- Parts book
Optional Equipment:
- Air Inlet System
- Air cleaner (Non canister disposable)
- Bases, Mounting & Fuel Tanks
- Integral tank base, 24 hours, UL142
- Audio & visual fuel alarm (@90% fuel level)
- Wide Base - Skid
- Fuel tank pill pipe & lockable cap
- Circuit Breaker
- 400A LSI
- 600A LSI
- 1200A LSI
- 800A LS/I
- Auxiliary contacts
- 600A LS/I
- 1200A LS/I
- 400A LS/I
- 800A LSI
- Control System
- Audible alarm Gp
- 16 -light NFPA 99/110 Annunciator
- Twist release, Red button emergency stop
- Ground fault relay
- 100A Load center
- Product link remote monitoring hardware
- 20A GFCI (Ground Fault Circuit Interrupter)
- Volt free contacts
- Enclosures
- Sound attenuated Level 2 enclosure (White)
- AC & DC Source lights
- E-Stop
- Exhaust System
- 6" Muffler - 25 dBA attenuation
- Manifold and turbocharger guards
- Flexible exhaust connection
- Generator
- Space heater
- Permanent magnet excitation (PMG) generator
- Starting System
- Battery charger (UL Certified)
- Jacket water heater
- Standard battery set: 1000 CCA, 90 amp/hr.
- General
- CSA Certification
- Extended Service Coverage
- UL2200 Certification
- Generator test report