ClickCease

D300 GC (60 Hz) Generator Set 11174

D300 GC (60 Hz) Generator Set
11174 D300 GC (60 Hz) Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Electric Power
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
300 ekW
Minimum Rating
300 ekW
Emissions/Fuel Strategy
EPA Stationary Emergency
Voltage
208 to 600 Volts

Financial Programs

  • Downpayment
    >49%
  • Period
    36 months
  • Rate
    0%
%
Period
Leasing agreement amount
Payment type
Annuity
Monthly payment
/ month

Generator Set Specifications

Maximum Rating
300 ekW
Minimum Rating
300 ekW
Emissions/Fuel Strategy
EPA Stationary Emergency
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1,800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C9 In-line 6, 4-cycle diesel
Bore
4.4 in
Stroke
5.9 in
Displacement
538 in³
Compression Ratio
16.3:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
HEUI
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
155.5 in
Width - Minimum
56.3 in
Width - Maximum
56.7 in
Height - Minimum
67.2 in
Height - Maximum
86.7 in
Dry Weight - Genset (minimum)
5,518.2 lb
Dry Weight - Genset (maximum)
6,929.1 lb

Standard Equipment:

  • Air Inlet System
    • Aftercooler core
    • Turbocharger
    • Air cleaner - Non canister, disposable
  • Control Panel
    • GCCP 1.2
  • Cooling System
    • Jacket water pump, gear driven, centrifugal
    • Thermostats and housing
    • Coolant drain valve
    • Radiator sight gauge
    • Blower fan and fan drive with guards
    • Radiator, package mounted
  • Exhaust System
    • Exhaust manifold - dry
  • Fuel System
    • Integral tank base, 24 hours, UL142
    • Fuel priming pump
    • Engine fuel transfer pump
    • Primary fuel filter w/integral water separator and secondary filter, spin on
  • Generator Set
    • Complete system designed & built at ISO 9001:2000 certified facilities
    • All protective devices and control functions simulated and checked
    • Factory tested to design specifications at full load conditions
  • Generators And Generator Attachments
    • IP23 Protection
    • 12 Leads
    • Insulation system, Class H
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • Voltage regulator (single phase sensing)
    • Easy access to AVR and terminals
    • Terminal box, IP22 RHS facing, bottom cable entry
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Shallow oil pan
    • Oil cooler
    • Fumes disposal to front of radiator
    • Oil drain with valve
    • Oil filler and dipstick
    • Oil filter, spin on
    • Lubricating oil, CK-4 (10W-30)
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Protection
    • Safety shutoff - High water temperature
    • Safety shutoff - Low oil pressure
    • Safety shutoff - Overspeed
  • Starting/charging System
    • 24-volt electric starting motor
    • 24V, 45 Amp Charging alternator
  • General
    • Lifting eyes
    • Vibration damper
    • Parts book

Optional Equipment:

  • Air Inlet System
    • Air cleaner (Non canister disposable)
  • Bases, Mounting & Fuel Tanks
    • Integral tank base, 24 hours, UL142
    • Audio & visual fuel alarm (@90% fuel level)
    • Wide Base - Skid
    • Fuel tank pill pipe & lockable cap
  • Circuit Breaker
    • 400A LSI
    • 600A LSI
    • 1200A LSI
    • 800A LS/I
    • Auxiliary contacts
    • 600A LS/I
    • 1200A LS/I
    • 400A LS/I
    • 800A LSI
  • Control System
    • Audible alarm Gp
    • 16 -light NFPA 99/110 Annunciator
    • Twist release, Red button emergency stop
    • Ground fault relay
    • 100A Load center
    • Product link remote monitoring hardware
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • Volt free contacts
  • Enclosures
    • Sound attenuated Level 2 enclosure (White)
    • AC & DC Source lights
    • E-Stop
  • Exhaust System
    • 6" Muffler - 25 dBA attenuation
    • Manifold and turbocharger guards
    • Flexible exhaust connection
  • Generator
    • Space heater
    • Permanent magnet excitation (PMG) generator
  • Starting System
    • Battery charger (UL Certified)
    • Jacket water heater
    • Standard battery set: 1000 CCA, 90 amp/hr.
  • General
    • CSA Certification
    • Extended Service Coverage
    • UL2200 Certification
    • Generator test report

Specifications

Generator Set Specifications

Maximum Rating
300 ekW
Minimum Rating
300 ekW
Emissions/Fuel Strategy
EPA Stationary Emergency
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1,800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C9 In-line 6, 4-cycle diesel
Bore
4.4 in
Stroke
5.9 in
Displacement
538 in³
Compression Ratio
16.3:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
HEUI
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
155.5 in
Width - Minimum
56.3 in
Width - Maximum
56.7 in
Height - Minimum
67.2 in
Height - Maximum
86.7 in
Dry Weight - Genset (minimum)
5,518.2 lb
Dry Weight - Genset (maximum)
6,929.1 lb

Standard/Optional Features

Standard Equipment:

  • Air Inlet System
    • Aftercooler core
    • Turbocharger
    • Air cleaner - Non canister, disposable
  • Control Panel
    • GCCP 1.2
  • Cooling System
    • Jacket water pump, gear driven, centrifugal
    • Thermostats and housing
    • Coolant drain valve
    • Radiator sight gauge
    • Blower fan and fan drive with guards
    • Radiator, package mounted
  • Exhaust System
    • Exhaust manifold - dry
  • Fuel System
    • Integral tank base, 24 hours, UL142
    • Fuel priming pump
    • Engine fuel transfer pump
    • Primary fuel filter w/integral water separator and secondary filter, spin on
  • Generator Set
    • Complete system designed & built at ISO 9001:2000 certified facilities
    • All protective devices and control functions simulated and checked
    • Factory tested to design specifications at full load conditions
  • Generators And Generator Attachments
    • IP23 Protection
    • 12 Leads
    • Insulation system, Class H
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • Voltage regulator (single phase sensing)
    • Easy access to AVR and terminals
    • Terminal box, IP22 RHS facing, bottom cable entry
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Shallow oil pan
    • Oil cooler
    • Fumes disposal to front of radiator
    • Oil drain with valve
    • Oil filler and dipstick
    • Oil filter, spin on
    • Lubricating oil, CK-4 (10W-30)
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Protection
    • Safety shutoff - High water temperature
    • Safety shutoff - Low oil pressure
    • Safety shutoff - Overspeed
  • Starting/charging System
    • 24-volt electric starting motor
    • 24V, 45 Amp Charging alternator
  • General
    • Lifting eyes
    • Vibration damper
    • Parts book

Optional Equipment:

  • Air Inlet System
    • Air cleaner (Non canister disposable)
  • Bases, Mounting & Fuel Tanks
    • Integral tank base, 24 hours, UL142
    • Audio & visual fuel alarm (@90% fuel level)
    • Wide Base - Skid
    • Fuel tank pill pipe & lockable cap
  • Circuit Breaker
    • 400A LSI
    • 600A LSI
    • 1200A LSI
    • 800A LS/I
    • Auxiliary contacts
    • 600A LS/I
    • 1200A LS/I
    • 400A LS/I
    • 800A LSI
  • Control System
    • Audible alarm Gp
    • 16 -light NFPA 99/110 Annunciator
    • Twist release, Red button emergency stop
    • Ground fault relay
    • 100A Load center
    • Product link remote monitoring hardware
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • Volt free contacts
  • Enclosures
    • Sound attenuated Level 2 enclosure (White)
    • AC & DC Source lights
    • E-Stop
  • Exhaust System
    • 6" Muffler - 25 dBA attenuation
    • Manifold and turbocharger guards
    • Flexible exhaust connection
  • Generator
    • Space heater
    • Permanent magnet excitation (PMG) generator
  • Starting System
    • Battery charger (UL Certified)
    • Jacket water heater
    • Standard battery set: 1000 CCA, 90 amp/hr.
  • General
    • CSA Certification
    • Extended Service Coverage
    • UL2200 Certification
    • Generator test report