ClickCease

C18 Generator Set 11184

C18 Generator Set
11184 C18 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Electric Power
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
500 ekW
Minimum Rating
455 ekW
Emissions/Fuel Strategy
U.S. EPA Tier 4 Final
Voltage
480 Volts

Financial Programs

  • Downpayment
    >49%
  • Period
    36 months
  • Rate
    0%
%
Period
Leasing agreement amount
Payment type
Annuity
Monthly payment
/ month

Generator Set Specifications

Maximum Rating
500 ekW
Minimum Rating
455 ekW
Emissions/Fuel Strategy
U.S. EPA Tier 4 Final
Voltage
480 Volts
Frequency
60 Hz
Speed
1,800 rpm
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
1,455.7 in
Stroke
7.2 in
Displacement
1,106.4 in³
Compression Ratio
14.5:1
Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Governor Type
Adem™A4

Standard Equipment:

  • Air Inlet
    • Air cleaner
  • Exhaust System
    • Exhaust manifold - dry
  • Cooling
    • Package mounted radiator
  • Fuel System
    • Fuel cooler
    • Engine fuel transfer pump
    • Primary fuel filter w/integral water separator and secondary filter
    • Fuel priming pump
    • Flexible fuel lines
  • Exhaust
    • Exhaust flange outlet
  • Fuel
    • Primary fuel filter with integral water separator
    • Fuel priming pump
    • Secondary fuel filters
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Power Termination
    • Busbar
  • Lube System
    • Oil filter and dipstick
    • Lubricating oil
    • Oil drain lines with valve; piped to edge of base
    • Fumes disposal, piped to front of radiator
    • Oil cooler
  • Control Panel
    • GCCP Genset Controller
  • Mounting
    • Rubber vibration isolators
  • Protection System
    • Safety shutoffs for: Higher water temperature - Overspeed - Low oil pressure
  • Cooling System
    • Thermostats and housing, full open temperature 92 deg C (198 deg F)
    • Coolant level sensor
    • Coolant level sight gauge
    • Fan and belt guards
    • Jacket water pump, gear driven, centrifugal
    • Coolant drain line with valve; terminated on edge of base
    • Caterpillar extended life coolant
  • Starting/charging
    • 24V, 45 Amp Charging alternator
    • 24 Volt electric starting motor
    • 24 volt starting motor
    • Batteries
  • General
    • Paint - Caterpillar yellow except rails and radiators gloss black
    • Paint, Caterpillar yellow
    • Operation and maintenance manual pack and OMM storage compartment
    • Parts book
    • Vibration damper
  • Control System
    • Local annunciator
    • Programmable Input / Output: 2 programmable digital inputs - 2 programmable relay outputs (Form A) - 2 programmable relay outputs (Form C)
    • Suitable for use as service equipment label
    • Separation plate
    • Control panel mounting location
    • Breaker box mounting location
    • Optional external analog input
    • Remote annunciators
    • GCCP 1.2
    • Communications: Customer data link (RS485 Modbus RTu) - Serial annunciator module data link for local and remote annunciator IVR - Integrated Voltage Regulation (Digital) - EM10 Excitation Module
    • Controls include: Run/auto/ stop/control - Speed adjust - Voltage adjust - Engine cycle crank - Emergency stop pushbutton
    • Digital indication for: rpm - DC volts - operating hours - Oil pressure (psi, kPa or bar) - Coolant temperature (C or F) - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - Power factor (per phase & average) - kW (per phase & average) - kVA (per phase & average) - kVAr (per phase and average) - kW-hr (total) - kVAr-hr (total)
    • Programmable protective relaying functions: Generator phase sequence - Over/under voltage (27/59) - Over/under frequency (81 o/u) - Overcurrent (50/51)
    • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - high coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level
    • Control panel options: Dust proof control panel - volt free contact - Device server - Ground fault relay
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Generator And Attachments
    • Segregated low voltage (AC/DC) wiring panel
    • Brushless, self-excited 2/3 pitch, random wound.
    • Insulation Class H and temperature rise
    • AREP generator
    • CIP - generators
    • IP23 Protection
    • Power center, IP22 bottom cable entry
  • Air Inlet System
    • Single element air filter
    • Air cleaner - Heavy duty
    • Air cleaner - Single element
  • Extended Service Coverage
    • Silver, Gold and Platinum coverage
  • Circuit Breakers
    • 3 Pole 100% rated

Optional Equipment:

  • Control System
    • Ground fault relay
    • Dust proof control panel
    • Breaker box mounting location
    • Volt free contact
    • Device server
    • Separation plate
    • Remote annunciators
    • GCCP 1.5
    • Local annunciator
    • Remote E-stop button
    • Optional external analog input
    • Control panel mounting
  • Exhaust
    • Industrial, residential, critical mufflers
  • Generator
    • Anti-condensation heater
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Oversize and premium generators
  • Power Termination
    • Circuit breakers, UL listed
  • Generators And Attachments
    • AREP generator
    • CIP generators
    • Space heater
    • Generator mounting and duct plate
  • Air Inlet System
    • Single element air filter
    • Dual element air cleaner
  • Certifications
    • Certificate of Compliance
    • IBC Certification wind load
  • Circuit Breakers
    • Motorized single circuit breaker
    • Neutral bars
    • Power cables
    • Dual breakers first circuit breaker (CB2) LS/I package mounted
    • Current transformers
    • Package mounted single circuit breakers
    • Dual breakers first circuit breaker (CB1) LS/I package mounted
    • Auxiliary contacts
  • Cooling System
    • Aftertreatment guard
    • Standard radiator
  • Enclosures
    • Sound attenuated enclosures
  • Exhaust System
    • Flange kits
    • Exhaust flexible fittings
  • Fuel System
    • 660 gallon base tank
  • Generator Attachments
    • Permanent magnet excitation (PMG) generator
  • Mounting System
    • Standard base wide
    • 5 Gallon spill containment
    • Optional CB shroud
    • Overfill prevention valve
    • Locking fuel fill
  • Starting / Charging System
    • Battery disconnect switch
    • Jacket water heater
    • Shore power control group
    • 10 Amp dual Battery charger
  • Tests
    • PGS Test report @ 0.8 power factor
    • 4 Hour factory test (un-witnessed)
    • PGS Test report @ 1.0 power factor
    • Generator test report

Specifications

Generator Set Specifications

Maximum Rating
500 ekW
Minimum Rating
455 ekW
Emissions/Fuel Strategy
U.S. EPA Tier 4 Final
Voltage
480 Volts
Frequency
60 Hz
Speed
1,800 rpm
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
1,455.7 in
Stroke
7.2 in
Displacement
1,106.4 in³
Compression Ratio
14.5:1
Aspiration
Air to Air Aftercooled
Fuel System
Electronic unit injection
Governor Type
Adem™A4

Standard/Optional Features

Standard Equipment:

  • Air Inlet
    • Air cleaner
  • Exhaust System
    • Exhaust manifold - dry
  • Cooling
    • Package mounted radiator
  • Fuel System
    • Fuel cooler
    • Engine fuel transfer pump
    • Primary fuel filter w/integral water separator and secondary filter
    • Fuel priming pump
    • Flexible fuel lines
  • Exhaust
    • Exhaust flange outlet
  • Fuel
    • Primary fuel filter with integral water separator
    • Fuel priming pump
    • Secondary fuel filters
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Power Termination
    • Busbar
  • Lube System
    • Oil filter and dipstick
    • Lubricating oil
    • Oil drain lines with valve; piped to edge of base
    • Fumes disposal, piped to front of radiator
    • Oil cooler
  • Control Panel
    • GCCP Genset Controller
  • Mounting
    • Rubber vibration isolators
  • Protection System
    • Safety shutoffs for: Higher water temperature - Overspeed - Low oil pressure
  • Cooling System
    • Thermostats and housing, full open temperature 92 deg C (198 deg F)
    • Coolant level sensor
    • Coolant level sight gauge
    • Fan and belt guards
    • Jacket water pump, gear driven, centrifugal
    • Coolant drain line with valve; terminated on edge of base
    • Caterpillar extended life coolant
  • Starting/charging
    • 24V, 45 Amp Charging alternator
    • 24 Volt electric starting motor
    • 24 volt starting motor
    • Batteries
  • General
    • Paint - Caterpillar yellow except rails and radiators gloss black
    • Paint, Caterpillar yellow
    • Operation and maintenance manual pack and OMM storage compartment
    • Parts book
    • Vibration damper
  • Control System
    • Local annunciator
    • Programmable Input / Output: 2 programmable digital inputs - 2 programmable relay outputs (Form A) - 2 programmable relay outputs (Form C)
    • Suitable for use as service equipment label
    • Separation plate
    • Control panel mounting location
    • Breaker box mounting location
    • Optional external analog input
    • Remote annunciators
    • GCCP 1.2
    • Communications: Customer data link (RS485 Modbus RTu) - Serial annunciator module data link for local and remote annunciator IVR - Integrated Voltage Regulation (Digital) - EM10 Excitation Module
    • Controls include: Run/auto/ stop/control - Speed adjust - Voltage adjust - Engine cycle crank - Emergency stop pushbutton
    • Digital indication for: rpm - DC volts - operating hours - Oil pressure (psi, kPa or bar) - Coolant temperature (C or F) - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - Power factor (per phase & average) - kW (per phase & average) - kVA (per phase & average) - kVAr (per phase and average) - kW-hr (total) - kVAr-hr (total)
    • Programmable protective relaying functions: Generator phase sequence - Over/under voltage (27/59) - Over/under frequency (81 o/u) - Overcurrent (50/51)
    • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - high coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level
    • Control panel options: Dust proof control panel - volt free contact - Device server - Ground fault relay
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Generator And Attachments
    • Segregated low voltage (AC/DC) wiring panel
    • Brushless, self-excited 2/3 pitch, random wound.
    • Insulation Class H and temperature rise
    • AREP generator
    • CIP - generators
    • IP23 Protection
    • Power center, IP22 bottom cable entry
  • Air Inlet System
    • Single element air filter
    • Air cleaner - Heavy duty
    • Air cleaner - Single element
  • Extended Service Coverage
    • Silver, Gold and Platinum coverage
  • Circuit Breakers
    • 3 Pole 100% rated

Optional Equipment:

  • Control System
    • Ground fault relay
    • Dust proof control panel
    • Breaker box mounting location
    • Volt free contact
    • Device server
    • Separation plate
    • Remote annunciators
    • GCCP 1.5
    • Local annunciator
    • Remote E-stop button
    • Optional external analog input
    • Control panel mounting
  • Exhaust
    • Industrial, residential, critical mufflers
  • Generator
    • Anti-condensation heater
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Oversize and premium generators
  • Power Termination
    • Circuit breakers, UL listed
  • Generators And Attachments
    • AREP generator
    • CIP generators
    • Space heater
    • Generator mounting and duct plate
  • Air Inlet System
    • Single element air filter
    • Dual element air cleaner
  • Certifications
    • Certificate of Compliance
    • IBC Certification wind load
  • Circuit Breakers
    • Motorized single circuit breaker
    • Neutral bars
    • Power cables
    • Dual breakers first circuit breaker (CB2) LS/I package mounted
    • Current transformers
    • Package mounted single circuit breakers
    • Dual breakers first circuit breaker (CB1) LS/I package mounted
    • Auxiliary contacts
  • Cooling System
    • Aftertreatment guard
    • Standard radiator
  • Enclosures
    • Sound attenuated enclosures
  • Exhaust System
    • Flange kits
    • Exhaust flexible fittings
  • Fuel System
    • 660 gallon base tank
  • Generator Attachments
    • Permanent magnet excitation (PMG) generator
  • Mounting System
    • Standard base wide
    • 5 Gallon spill containment
    • Optional CB shroud
    • Overfill prevention valve
    • Locking fuel fill
  • Starting / Charging System
    • Battery disconnect switch
    • Jacket water heater
    • Shore power control group
    • 10 Amp dual Battery charger
  • Tests
    • PGS Test report @ 0.8 power factor
    • 4 Hour factory test (un-witnessed)
    • PGS Test report @ 1.0 power factor
    • Generator test report

Attachments