Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Financial Programs
- Downpayment>49%
- Period36 months
- Rate0%
%
Period
Leasing agreement amount
Payment type
Annuity
Monthly payment
/ month
Generator Set Specifications
- Maximum Rating
- 1,250 ekW
- Minimum Rating
- 830 ekW
- Emissions/Fuel Strategy
- Low Fuel, Tier 2 Nonroad Stds
- Voltage
- 220 to 4,160 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby, Mission Critical, Prime, Continuous
Engine Specifications
- Engine Model
- C32 TA, V-12, 4-Stroke Water-Cooled Diesel
- Bore
- 5.71 in
- Stroke
- 6.38 in
- Displacement
- 1,958.86 in³
- Compression Ratio
- 15.0:1
- Aspiration
- TA
- Fuel System
- MEUI
- Governor Type
- Adem™A4
Generator Set Dimensions
- Length - Minimum
- 164 in
- Length - Maximum
- 172.7 in
- Width - Minimum
- 66.3 in
- Width - Maximum
- 87.7 in
- Height - Minimum
- 85.1 in
- Height - Maximum
- 86.4 in
- Dry Weight - Genset (minimum)
- 14,700 lb
- Dry Weight - Genset (maximum)
- 16,755 lb
Standard Equipment:
- Air Inlet System
- Single element canister type with service indicator
- Control Panel
- Warning shutdowns
- EMCP 4.2B
- Digital Indicators
- Communications
- Control features
- Programmable protective relaying functions
- Cooling System
- Caterpillar extended life coolant
- ATAAC
- Coolant drain line with valve
- Low coolant level sensor
- Fan and belt guards
- Radiator fan and fan drive
- Exhaust System
- 203 mm (8 in) ID round flanged outlet
- Exhaust manifold - dry
- Fuel System
- Fuel cooler
- Fuel priming pump
- Secondary fuel filters
- Primary fuel filter with water separator
- General
- RH service
- Caterpillar yellow with high gloss black rails & radiator
- SAE standard rotation
- Flywheel and flywheel housing-SAE
- Generators And Attachments
- Class H temperature rise at 40C ambient
- 3 Phase brushless
- Permanent magnet excitation (PMG)
- Winding temperature detectors
- Integrated voltage regulator (IVR)
- Reactive droop
- IEC standard hole pattern
- NEMA Class H insulation
- Busbar connections, top center mounted, top cable entry
- Salient pole
- 6 Lead
- Internal excitation (IE)
- Governing System
- ADEM(tm) A4
- Lube System
- Gear type lube oil pump
- Oil drain lines and valve
- Fumes disposal
- Lubricating oil
- Integral lube Oil cooler
- Oil filter, filler and dipstick
- Mounting System
- Rubber anti-vibration mounts
- Rails - Engine/generator/radiator mounting
- Power Termination
- Busbar
- Starting And Charging
- 45 Amp Charging alternator
- 24 Volt electric starting motor
- Battery disconnect switch
- Battery, rack and cables
Optional Equipment:
- Air Inlet System
- Standard air cleaners
- Heavy duty air cleaner
- Dual element air cleaner
- Circuit Breakers
- Shrouds
- 1600, 2000, 2500 and 3200 Amp, 3 Pole, IEC-Rated Circuit breakers
- Center posts busbars
- Enclosures - Control packaging
- 400, 800, 1200, 1600, 2000, 2500 and 3000 Amp, 3 Pole, UL-100% Rated Circuit breakers
- Circuit breaker wiring groups
- Power connection covers
- Cable supports
- 800, 1600, 2000, 2500 and 3200 Amp, 4 Pole, IEC rated Circuit breakers
- Control Panels
- EMCP 4.3, EMCP 4.4
- Cooling System
- High ambient radiator
- Extended life coolant
- Standard radiator
- Radiator duct flange
- Certified radiator
- Enclosures
- Premium sound attenuated enclosure
- Cold weather bundle
- Color options
- DC lighting package
- Sound attenuated enclosure
- AC Panel, outlets and lights
- Panel bracket
- Enclosure fuel tank options
- Enclosure louvers - fixed and motorized
- Exhaust System
- Elbow mounting kit
- Mufflers
- Guard and shield system
- Flange and exhaust expanders
- Flexible fittings
- All C32 engines have 203 mm (8 in) exhaust outlets
- Flanges
- Exhaust through the wall kit
- General
- US aid emblem
- Special paint
- Generator And Attachments
- Medium voltage optional generators
- Low voltage optional generators
- Lube System
- Oil level regulator
- Oil pan
- Prelube manual sump pump
- Mounting System
- Spring type vibration isolators
- IBC vibration isolators
- Mounting base types
- Standard package isolators
- Power Connections
- Center post busbars
- Low voltage connection cables
- Neutral grounding connection
- Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
- Special Tests / Reports
- Standard engine test
- IBC seismic Certifications
- PGS Test report @ 1.0 power factor
- Custom generator TVA report
- Generator test report
- Standard genset Torsional Vibration Analysis (TVA) report
- PGS Test report @ 0.8 power factor
- CSA test and certification
- OSHPD seismic Certifications
- Starting / Charging
- 10 Amp enclosure Battery charger
- 35 Amp Battery charger
- Space heater
- Jacket water heater
- Electric starting motor - Standard/heavy duty
- Heavy duty starting system
- 10 Amp Battery charger
- 20 Amp Battery charger
Specifications
Generator Set Specifications
- Maximum Rating
- 1,250 ekW
- Minimum Rating
- 830 ekW
- Emissions/Fuel Strategy
- Low Fuel, Tier 2 Nonroad Stds
- Voltage
- 220 to 4,160 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby, Mission Critical, Prime, Continuous
Engine Specifications
- Engine Model
- C32 TA, V-12, 4-Stroke Water-Cooled Diesel
- Bore
- 5.71 in
- Stroke
- 6.38 in
- Displacement
- 1,958.86 in³
- Compression Ratio
- 15.0:1
- Aspiration
- TA
- Fuel System
- MEUI
- Governor Type
- Adem™A4
Generator Set Dimensions
- Length - Minimum
- 164 in
- Length - Maximum
- 172.7 in
- Width - Minimum
- 66.3 in
- Width - Maximum
- 87.7 in
- Height - Minimum
- 85.1 in
- Height - Maximum
- 86.4 in
- Dry Weight - Genset (minimum)
- 14,700 lb
- Dry Weight - Genset (maximum)
- 16,755 lb
Standard/Optional Features
Standard Equipment:
- Air Inlet System
- Single element canister type with service indicator
- Control Panel
- Warning shutdowns
- EMCP 4.2B
- Digital Indicators
- Communications
- Control features
- Programmable protective relaying functions
- Cooling System
- Caterpillar extended life coolant
- ATAAC
- Coolant drain line with valve
- Low coolant level sensor
- Fan and belt guards
- Radiator fan and fan drive
- Exhaust System
- 203 mm (8 in) ID round flanged outlet
- Exhaust manifold - dry
- Fuel System
- Fuel cooler
- Fuel priming pump
- Secondary fuel filters
- Primary fuel filter with water separator
- General
- RH service
- Caterpillar yellow with high gloss black rails & radiator
- SAE standard rotation
- Flywheel and flywheel housing-SAE
- Generators And Attachments
- Class H temperature rise at 40C ambient
- 3 Phase brushless
- Permanent magnet excitation (PMG)
- Winding temperature detectors
- Integrated voltage regulator (IVR)
- Reactive droop
- IEC standard hole pattern
- NEMA Class H insulation
- Busbar connections, top center mounted, top cable entry
- Salient pole
- 6 Lead
- Internal excitation (IE)
- Governing System
- ADEM(tm) A4
- Lube System
- Gear type lube oil pump
- Oil drain lines and valve
- Fumes disposal
- Lubricating oil
- Integral lube Oil cooler
- Oil filter, filler and dipstick
- Mounting System
- Rubber anti-vibration mounts
- Rails - Engine/generator/radiator mounting
- Power Termination
- Busbar
- Starting And Charging
- 45 Amp Charging alternator
- 24 Volt electric starting motor
- Battery disconnect switch
- Battery, rack and cables
Optional Equipment:
- Air Inlet System
- Standard air cleaners
- Heavy duty air cleaner
- Dual element air cleaner
- Circuit Breakers
- Shrouds
- 1600, 2000, 2500 and 3200 Amp, 3 Pole, IEC-Rated Circuit breakers
- Center posts busbars
- Enclosures - Control packaging
- 400, 800, 1200, 1600, 2000, 2500 and 3000 Amp, 3 Pole, UL-100% Rated Circuit breakers
- Circuit breaker wiring groups
- Power connection covers
- Cable supports
- 800, 1600, 2000, 2500 and 3200 Amp, 4 Pole, IEC rated Circuit breakers
- Control Panels
- EMCP 4.3, EMCP 4.4
- Cooling System
- High ambient radiator
- Extended life coolant
- Standard radiator
- Radiator duct flange
- Certified radiator
- Enclosures
- Premium sound attenuated enclosure
- Cold weather bundle
- Color options
- DC lighting package
- Sound attenuated enclosure
- AC Panel, outlets and lights
- Panel bracket
- Enclosure fuel tank options
- Enclosure louvers - fixed and motorized
- Exhaust System
- Elbow mounting kit
- Mufflers
- Guard and shield system
- Flange and exhaust expanders
- Flexible fittings
- All C32 engines have 203 mm (8 in) exhaust outlets
- Flanges
- Exhaust through the wall kit
- General
- US aid emblem
- Special paint
- Generator And Attachments
- Medium voltage optional generators
- Low voltage optional generators
- Lube System
- Oil level regulator
- Oil pan
- Prelube manual sump pump
- Mounting System
- Spring type vibration isolators
- IBC vibration isolators
- Mounting base types
- Standard package isolators
- Power Connections
- Center post busbars
- Low voltage connection cables
- Neutral grounding connection
- Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
- Special Tests / Reports
- Standard engine test
- IBC seismic Certifications
- PGS Test report @ 1.0 power factor
- Custom generator TVA report
- Generator test report
- Standard genset Torsional Vibration Analysis (TVA) report
- PGS Test report @ 0.8 power factor
- CSA test and certification
- OSHPD seismic Certifications
- Starting / Charging
- 10 Amp enclosure Battery charger
- 35 Amp Battery charger
- Space heater
- Jacket water heater
- Electric starting motor - Standard/heavy duty
- Heavy duty starting system
- 10 Amp Battery charger
- 20 Amp Battery charger