Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Financial Programs
- Downpayment>49%
- Period36 months
- Rate0%
%
Period
Leasing agreement amount
Payment type
Annuity
Monthly payment
/ month
Generator Set Specifications
- Maximum Rating
- 200 ekW
- Minimum Rating
- 200 ekW
- Emissions/Fuel Strategy
- U.S. EPA Cert., Tier 3
- Voltage
- 208 to 600 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- C7.1 I-6, 4-Cycle Diesel
- Bore
- 4.1 in
- Stroke
- 5.31 in
- Displacement
- 428 in³
- Compression Ratio
- 16.7:1
- Aspiration
- Turbocharged, Air to Air Aftercooled
- Fuel System
- Electronic, Common Rail
- Governor Type
- ADEM™A4
Generator Set Dimensions
- Length - Maximum
- 103.7 in
- Width - Maximum
- 51.2 in
- Height - Maximum
- 58.7 in
- Dry Weight - Genset (maximum)
- 3,917 lb
Standard Equipment:
- Air Inlet System
- Air cleaner; light duty with disposable element
- Control Panels
- GCCP 1.2 Control panel
- Cooling System
- Coolant drain line with valves
- Radiator and cooling fan with guards
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
- Generator And Generator Attachments
- Segregated low voltage (AC/DC) wiring panel
- Voltage regulator (single phase sensing)
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- Tower panel, IP22, bottom cable entry
- 12 Leads
- IP23 Protection
- Exhaust System
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
- Fuel System
- Standard open set fuel tank/base supplied
- Base, formed steel with single wall integral 24-hour fuel tank
- Lube System
- Oil drain line with valve
- Lubricating oil
- Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provision and drag points
- Termination points for coolant and lube oil drain lines
- Starting / Charging System
- 24V battery with rack and cables
- Governing System
- Mechanical and electrical governing system - model dependent
- General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
- Alternator System
- Quatrature droop king
- Permanent magnet excitation (PMG)
- R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
- Alternator removal
- Anti-condensation heater
- 3 Phase sensing
- Optional LC Frame alternator with coastal insulation protection
- Circuit Breakers
- Padlockable breaker device
- 4 Pole 250A, 400A and 630A Circuit breakers
- Control Panel Options
- Earth leakage (2 wire only)
- Panel mounted audible alarm
- Speed adjust potentiometer
- Overload shutdown via breaker
- Emergency stop with key
- Earth fault (2 wire only)
- Control panel heater
- Battery charger
- Speed adjust contacts
- Volt free contacts
- Control System
- Volt free contacts for generator set running
- GCCP 1.2
- Volt free contacts for common alarm
- Static battery charger
- Cooling System
- Low coolant temperature
- Coolant heater
- Low coolant level shutdown
- Enclosures
- Sound attenuated level 2 enclosure
- Mounting Options
- Silencer installation kit
- Battery removal
- Electronic governor
- Industrial silencer removal
- Residential silencer
- Fuel Systems
- Open set narrow tankbase
- Low fuel level shutdown
- Low fuel level alarm
- Compact skidbase for open sets
- DEFRA bunded fuel tank
- High fuel level alarm
- Skidbase for CALG enclosure sets
- Test Reports
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
- General
- Stone guards/radiator trans flange
- Global Certifications
- Certification for CIS
- Power Termination
- Circuit breaker, IEC, 4 pole
- Accessories / Miscellaneous
- Packing case - canopied set
- Packing case - compact set
Specifications
Generator Set Specifications
- Maximum Rating
- 200 ekW
- Minimum Rating
- 200 ekW
- Emissions/Fuel Strategy
- U.S. EPA Cert., Tier 3
- Voltage
- 208 to 600 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- C7.1 I-6, 4-Cycle Diesel
- Bore
- 4.1 in
- Stroke
- 5.31 in
- Displacement
- 428 in³
- Compression Ratio
- 16.7:1
- Aspiration
- Turbocharged, Air to Air Aftercooled
- Fuel System
- Electronic, Common Rail
- Governor Type
- ADEM™A4
Generator Set Dimensions
- Length - Maximum
- 103.7 in
- Width - Maximum
- 51.2 in
- Height - Maximum
- 58.7 in
- Dry Weight - Genset (maximum)
- 3,917 lb
Standard/Optional Features
Standard Equipment:
- Air Inlet System
- Air cleaner; light duty with disposable element
- Control Panels
- GCCP 1.2 Control panel
- Cooling System
- Coolant drain line with valves
- Radiator and cooling fan with guards
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
- Generator And Generator Attachments
- Segregated low voltage (AC/DC) wiring panel
- Voltage regulator (single phase sensing)
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- Tower panel, IP22, bottom cable entry
- 12 Leads
- IP23 Protection
- Exhaust System
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
- Fuel System
- Standard open set fuel tank/base supplied
- Base, formed steel with single wall integral 24-hour fuel tank
- Lube System
- Oil drain line with valve
- Lubricating oil
- Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provision and drag points
- Termination points for coolant and lube oil drain lines
- Starting / Charging System
- 24V battery with rack and cables
- Governing System
- Mechanical and electrical governing system - model dependent
- General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
- Alternator System
- Quatrature droop king
- Permanent magnet excitation (PMG)
- R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
- Alternator removal
- Anti-condensation heater
- 3 Phase sensing
- Optional LC Frame alternator with coastal insulation protection
- Circuit Breakers
- Padlockable breaker device
- 4 Pole 250A, 400A and 630A Circuit breakers
- Control Panel Options
- Earth leakage (2 wire only)
- Panel mounted audible alarm
- Speed adjust potentiometer
- Overload shutdown via breaker
- Emergency stop with key
- Earth fault (2 wire only)
- Control panel heater
- Battery charger
- Speed adjust contacts
- Volt free contacts
- Control System
- Volt free contacts for generator set running
- GCCP 1.2
- Volt free contacts for common alarm
- Static battery charger
- Cooling System
- Low coolant temperature
- Coolant heater
- Low coolant level shutdown
- Enclosures
- Sound attenuated level 2 enclosure
- Mounting Options
- Silencer installation kit
- Battery removal
- Electronic governor
- Industrial silencer removal
- Residential silencer
- Fuel Systems
- Open set narrow tankbase
- Low fuel level shutdown
- Low fuel level alarm
- Compact skidbase for open sets
- DEFRA bunded fuel tank
- High fuel level alarm
- Skidbase for CALG enclosure sets
- Test Reports
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
- General
- Stone guards/radiator trans flange
- Global Certifications
- Certification for CIS
- Power Termination
- Circuit breaker, IEC, 4 pole
- Accessories / Miscellaneous
- Packing case - canopied set
- Packing case - compact set