ClickCease

DG350-2 (Single-phase) 15340

DG350-2 (Single-phase)
15340 DG350-2 (Single-phase)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Electric Power
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Frequency
60 Hz
Natural Gas Rating
350 eKW
Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Application
Engine Model
G21.9L Spark-Ignited

Financial Programs

  • Downpayment
    >49%
  • Period
    36 months
  • Rate
    0%
%
Period
Leasing agreement amount
Payment type
Annuity
Monthly payment
/ month

Generator Set Specifications

Frequency
60 Hz
Natural Gas Rating
350 eKW
Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Application
Fuel Type
Natural Gas
Displacement
1,336.42 in³
Speed
1,800 rpm

Engine Specifications

Engine Model
G21.9L Spark-Ignited
Compression Ratio
10.1
Fuel System
Carburetor, Down Draft
Governor Type
Electronic
Aspiration
Turbocharged - Aftercooled
Bore
5.03 in
Stroke
5.6 in

Generator Set Dimensions

Length
154.4 in
Width
71 in
Height
67.6 in
Weight
8,274 lb

Standard Equipment:

  • Cooling
    • Closed coolant recovery system
    • 50/50 Ethylene glycol antifreeze
    • Factory-installed radiator
    • Radiator and cooling fan complete with protective guards
    • Standard ambient temperatures up to 50°C (122°F)
  • Air Inlet
    • Single element air filter
  • Fuel
    • Primary and secondary fuel shut-off
    • Fuel pressure test po
    • Low fuel pressure switch
    • Dual lock off valves
    • NPT connection
    • Natural Gas or LP Vapor
  • Exhaust
    • Exhaust outlet with 3” pipe
  • Generator
    • Full load capacity alternator
    • Class H insulation material
    • Permanent magnet excitation
    • Permanent magnet excitation
    • Integrated Voltage Regulator
    • Class H insulation material
    • IP23 Protection
    • Matched to the performance and output characteristics of Cat engines
    • Full load capacity alternator
  • Controls
    • EMCP 4.2 Series generator set controller
  • Mounting
    • Vibration isolaton (puck type)
    • Rubber vibration isolators
  • Electric Starting And/or Prelube
    • Engine electrical system
    • Battery cables
    • Solenoid activated starter motor
    • Solenoid activated starter motor
  • Electric Power - Package Serial Number Prefix
    • Battery charging alternator
  • Governor
    • Electronic governor (non adjustable)
  • Control Panel
    • EMCP 4.2 Series generator set controller
  • Starting/charging
    • 12 volt starting motor
    • Batteries with rack and cables

Optional Equipment:

  • Starting/charging
    • Charging alternator
    • Battery charger – UL Listed 10 amp
    • Battery heater
    • Jacket water heater
  • General
    • UL 2200 package
    • CSA Certification
    • Suitable for Use as Service Equipment (SUSE)
    • Automatic transfer switches (ATS)
    • Enclosures: sound attenuated, weather protective
  • Generator
    • Anti-condensation heater
    • Thermal magnetic or electronic trip MCCBs
    • Shunt trip and auxiliary contact breaker
    • Excitation: [ ] Permanent Magnet Excited (PM)
    • Oversize and premium generators
    • Anti-condensation heater

Specifications

Generator Set Specifications

Frequency
60 Hz
Natural Gas Rating
350 eKW
Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Application
Fuel Type
Natural Gas
Displacement
1,336.42 in³
Speed
1,800 rpm

Engine Specifications

Engine Model
G21.9L Spark-Ignited
Compression Ratio
10.1
Fuel System
Carburetor, Down Draft
Governor Type
Electronic
Aspiration
Turbocharged - Aftercooled
Bore
5.03 in
Stroke
5.6 in

Generator Set Dimensions

Length
154.4 in
Width
71 in
Height
67.6 in
Weight
8,274 lb

Standard/Optional Features

Standard Equipment:

  • Cooling
    • Closed coolant recovery system
    • 50/50 Ethylene glycol antifreeze
    • Factory-installed radiator
    • Radiator and cooling fan complete with protective guards
    • Standard ambient temperatures up to 50°C (122°F)
  • Air Inlet
    • Single element air filter
  • Fuel
    • Primary and secondary fuel shut-off
    • Fuel pressure test po
    • Low fuel pressure switch
    • Dual lock off valves
    • NPT connection
    • Natural Gas or LP Vapor
  • Exhaust
    • Exhaust outlet with 3” pipe
  • Generator
    • Full load capacity alternator
    • Class H insulation material
    • Permanent magnet excitation
    • Permanent magnet excitation
    • Integrated Voltage Regulator
    • Class H insulation material
    • IP23 Protection
    • Matched to the performance and output characteristics of Cat engines
    • Full load capacity alternator
  • Controls
    • EMCP 4.2 Series generator set controller
  • Mounting
    • Vibration isolaton (puck type)
    • Rubber vibration isolators
  • Electric Starting And/or Prelube
    • Engine electrical system
    • Battery cables
    • Solenoid activated starter motor
    • Solenoid activated starter motor
  • Electric Power - Package Serial Number Prefix
    • Battery charging alternator
  • Governor
    • Electronic governor (non adjustable)
  • Control Panel
    • EMCP 4.2 Series generator set controller
  • Starting/charging
    • 12 volt starting motor
    • Batteries with rack and cables

Optional Equipment:

  • Starting/charging
    • Charging alternator
    • Battery charger – UL Listed 10 amp
    • Battery heater
    • Jacket water heater
  • General
    • UL 2200 package
    • CSA Certification
    • Suitable for Use as Service Equipment (SUSE)
    • Automatic transfer switches (ATS)
    • Enclosures: sound attenuated, weather protective
  • Generator
    • Anti-condensation heater
    • Thermal magnetic or electronic trip MCCBs
    • Shunt trip and auxiliary contact breaker
    • Excitation: [ ] Permanent Magnet Excited (PM)
    • Oversize and premium generators
    • Anti-condensation heater