The EMCP 4.4 Master Control Panel is a wall mounted system that monitors and controls up to eight engine generators for operation in parallel with or without a single utility source.
Financial Programs
- Downpayment>49%
- Period36 months
- Rate0%
%
Period
Leasing agreement amount
Payment type
Annuity
Monthly payment
/ month
Technical Summary
- Configuration
- Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.
- Modes of Operation
- Emergency standby, island, utility paralleling
- Application
- LV and MV (208V - 38 kV)
Generator Protective Devices
- ANSI Protective Devices
- 15/25, 27/59, 81 O/U, 32, 40, 50, 51
Utility Protective Devices
- ANSI Protective Devices
- 15/25. 27/59, 81 O/U, 32,47 (Industrial Grade)
Environmental Parameters
- Certifications
- IBC, CBC, UBC & OSHPD Certified
- Control Panel Enclosure
- NEMA 1 wall-mounted construction
- Operating Temperature
- 0°C to 50°C
- Storage Temperature
- -20°C to +60°C
- Low Voltage Standards
- NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1,558 or UL 891, NFPA 110, NFPA 99 and NFPA 70
- Medium Voltage Standards
- NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1,110
Standard Equipment:
- Configuration
- Wall mounted supervisory control system provides centralized monitoring and control of up to eight generators equipped with EMCP4.4 paralleling control panels
- Application
- LV and MV (208V - 15 kV) 50/60Hz
- Operating Temperature
- 0-50 C
- Medium Voltage Standards
- UL 508A
- Emergency Transfer Load Manager Standard Equipment
- Data Table Interface
- 19" Color Touchscreen
Optional Equipment:
- Emergency Transfer Load Manager Optional Equipment
- Utility Monitoring and Circuit Breaker Control I/O provided in XLM version of Master Control Panel provided in XLM version of Master Control Panel
- Related Products - Attachments
- Diesel Generator Sets - C9, C13, C15, C18, C27, C32, 3500, C175
Specifications
Technical Summary
- Configuration
- Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.
- Modes of Operation
- Emergency standby, island, utility paralleling
- Application
- LV and MV (208V - 38 kV)
Generator Protective Devices
- ANSI Protective Devices
- 15/25, 27/59, 81 O/U, 32, 40, 50, 51
Utility Protective Devices
- ANSI Protective Devices
- 15/25. 27/59, 81 O/U, 32,47 (Industrial Grade)
Environmental Parameters
- Certifications
- IBC, CBC, UBC & OSHPD Certified
- Control Panel Enclosure
- NEMA 1 wall-mounted construction
- Operating Temperature
- 0°C to 50°C
- Storage Temperature
- -20°C to +60°C
- Low Voltage Standards
- NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1,558 or UL 891, NFPA 110, NFPA 99 and NFPA 70
- Medium Voltage Standards
- NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1,110
Standard/Optional Features
Standard Equipment:
- Configuration
- Wall mounted supervisory control system provides centralized monitoring and control of up to eight generators equipped with EMCP4.4 paralleling control panels
- Application
- LV and MV (208V - 15 kV) 50/60Hz
- Operating Temperature
- 0-50 C
- Medium Voltage Standards
- UL 508A
- Emergency Transfer Load Manager Standard Equipment
- Data Table Interface
- 19" Color Touchscreen
Optional Equipment:
- Emergency Transfer Load Manager Optional Equipment
- Utility Monitoring and Circuit Breaker Control I/O provided in XLM version of Master Control Panel provided in XLM version of Master Control Panel
- Related Products - Attachments