Generator Set Specifications
- Maximum Standby Rating
- 500 ekW @0.8pf
- Fuel Type
- Natural Gas
- Emissions/Fuel Strategy
- U.S. EPA Certified for Emergency Only Stationary Genset
- Frequency
- 60 Hz
- RPM
- 1,800 rpm
Engine Specifications
- Engine Model
- G3,412
- Displacement
- 1,649 in³
- Aspiration
- NA
- Bore
- 5.4 in
- Stroke
- 6 in
Generator Set Dimensions
- Length
- 165 in
- Width
- 85.25 in
- Height
- 86 in
- Dry Weight - Genset
- 14,700 lb
Standard Equipment:
- Air Inlet
- Two-element single-stage air cleaner with enclosure and service indicator
- Dual air cleaners, 1 per side, with service indicator
- Control Panel
- EMCP 4.3
- Cooling
- Package mounted radiator
- LH or RG connections when radiator is not selected
- Engine driven pumps for jacket water and separate circuit aftercooler
- Jacket water and SCAC thermostats
- Fuel
- Pipeline Natural Gas: 800-1000 BTU/scf and 70-100 Methane Number
- Gas Train: NFPA37 and CSA B149.3
- Exhaust
- Dry exhaust manifolds, insulated and shielded
- Fuel System
- Engine-installed electronic control valve
- Gas pressure regulator
- 24V DC energized-to-run (ETR) gas shutoff valve
- General
- Paint- Caterpillar Yellow with gloss black rails and radiators
- Operation and maintenance manuals
- RH Service
- Parts book
- Crankshaft vibration damper and guard
- Lubrication
- Cartridge style oil filter
- Gear type lube oil pump
- Generator
- Caterpillar's Digital Voltage Regulator (CDVR) including reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, and a min/max exciter
- Anti-condensation space heater
- Permanent Magnet Excitiation
- Winding temperature detectors
- Governing System
- ADEM A4
- Ignition System
- Electronic Ignition System (controlled by ADEM A4)
- Individual Cylinder Detonation Sensitive Timing (DST)
- Starting/charging
- Electric Starter
- 24V DC starting motors
Optional Equipment:
- Air Inlet
- Air cleaner with precleaner
- Circuit Breakers
- S LSI
- Frame mounting
- Right, left, rear mounted
- Control Panel
- Local alarm module
- Local PC monitoring
- Remote PC monitoring
- Remote annunciator
- Cooling
- Inlet/Outlet connections
- Coolant level drain line with valves, fan with guard
- Exhaust
- Flexible fittings
- 15, 25 dBA Attenuation
- General
- Digital diagnostic tool
- Tool set
- US AID emblem
- Generator
- Cable access box
- Bearing temperature detectors
- Starting/charging
- Battery with cables and rack (shipped loose)
- 10A, 24VDC battery charger
- Jacket water heater
Specifications
Generator Set Specifications
- Maximum Standby Rating
- 500 ekW @0.8pf
- Fuel Type
- Natural Gas
- Emissions/Fuel Strategy
- U.S. EPA Certified for Emergency Only Stationary Genset
- Frequency
- 60 Hz
- RPM
- 1,800 rpm
Engine Specifications
- Engine Model
- G3,412
- Displacement
- 1,649 in³
- Aspiration
- NA
- Bore
- 5.4 in
- Stroke
- 6 in
Generator Set Dimensions
- Length
- 165 in
- Width
- 85.25 in
- Height
- 86 in
- Dry Weight - Genset
- 14,700 lb
Standard/Optional Features
Standard Equipment:
- Air Inlet
- Two-element single-stage air cleaner with enclosure and service indicator
- Dual air cleaners, 1 per side, with service indicator
- Control Panel
- EMCP 4.3
- Cooling
- Package mounted radiator
- LH or RG connections when radiator is not selected
- Engine driven pumps for jacket water and separate circuit aftercooler
- Jacket water and SCAC thermostats
- Fuel
- Pipeline Natural Gas: 800-1000 BTU/scf and 70-100 Methane Number
- Gas Train: NFPA37 and CSA B149.3
- Exhaust
- Dry exhaust manifolds, insulated and shielded
- Fuel System
- Engine-installed electronic control valve
- Gas pressure regulator
- 24V DC energized-to-run (ETR) gas shutoff valve
- General
- Paint- Caterpillar Yellow with gloss black rails and radiators
- Operation and maintenance manuals
- RH Service
- Parts book
- Crankshaft vibration damper and guard
- Lubrication
- Cartridge style oil filter
- Gear type lube oil pump
- Generator
- Caterpillar's Digital Voltage Regulator (CDVR) including reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, and a min/max exciter
- Anti-condensation space heater
- Permanent Magnet Excitiation
- Winding temperature detectors
- Governing System
- ADEM A4
- Ignition System
- Electronic Ignition System (controlled by ADEM A4)
- Individual Cylinder Detonation Sensitive Timing (DST)
- Starting/charging
- Electric Starter
- 24V DC starting motors
Optional Equipment:
- Air Inlet
- Air cleaner with precleaner
- Circuit Breakers
- S LSI
- Frame mounting
- Right, left, rear mounted
- Control Panel
- Local alarm module
- Local PC monitoring
- Remote PC monitoring
- Remote annunciator
- Cooling
- Inlet/Outlet connections
- Coolant level drain line with valves, fan with guard
- Exhaust
- Flexible fittings
- 15, 25 dBA Attenuation
- General
- Digital diagnostic tool
- Tool set
- US AID emblem
- Generator
- Cable access box
- Bearing temperature detectors
- Starting/charging
- Battery with cables and rack (shipped loose)
- 10A, 24VDC battery charger
- Jacket water heater